Factor of Safety
Factor of Safety (FoS or n) is the ratio of a structure's maximum load capacity to the design load.
Why Use Factor of Safety?
- Uncertainty in loads, material properties, manufacturing
- Material variability — batch-to-batch differences
- Environmental effects — temperature, corrosion
- Unknown loading conditions — dynamic effects, impact
- Consequences of failure — safety-critical vs. non-critical
Types of FoS
Based on Yield Strength
Prevents plastic deformation.
Based on Ultimate Strength
Prevents fracture.
Based on Fatigue
- S_e = Fatigue endurance limit
Typical FoS Values
| Application | FoS (Yield) | FoS (Ultimate) |
|---|---|---|
| Aerospace | 1.2 - 1.5 | 2.0 - 2.5 |
| Structural (steel) | 1.5 | 2.5 |
| Machinery | 2.0 - 3.0 | 3.0 - 5.0 |
| Pressure vessels | 3.0 - 4.0 | 4.0 - 5.0 |
| Lifting equipment | 4.0 - 5.0 | 5.0 - 8.0 |
Design Approaches
Allowable Stress Design (ASD)
Apply factor to material strength.
Load Factor Design (LFD)
- φ = Resistance factor
- γ = Load factor
- R_n = Nominal resistance
- Q_i = Load effects
Apply factors to both loads and material.
Considerations
- Higher FoS = heavier, more expensive design
- Too low = risk of failure
- Code minimums often dictate minimum FoS
- FoS is not a "magic number" — must be justified