Column Buckling
Buckling is a mode of failure where a compressive member suddenly deflects laterally.
Critical Load
The load at which a perfectly straight column becomes unstable:
- E = Modulus of elasticity
- I = Minimum second moment of area
- L = Unbraced length
- K = Effective length factor
Effective Length Factor (K)
| End Conditions | K |
|---|---|
| Both ends pinned | 1.0 |
| One end fixed, one free | 2.0 |
| Both ends fixed | 0.5 |
| One fixed, one pinned | 0.7 |
Slenderness Ratio
- r = radius of gyration = √(I/A)
Classification
| Slenderness | Behavior |
|---|---|
| Short (λ < 20) | Material failure (crushing) |
| Intermediate (20 < λ < 100) | Inelastic buckling |
| Long (λ > 100) | Elastic buckling (Euler) |
Euler Buckling Load
For long columns (elastic buckling):
Valid when:
Johnson Buckling
For intermediate columns (inelastic):
Design Considerations
slenderness Ratio Limits
- Steel: KL/r ≤ 200
- Aluminum: KL/r ≤ 100-150
- Concrete: slenderness < 100
Column Sections
- Weak axis buckling — often critical (lowest I)
- Use stiffened sections (I-beam, box)
- Lateral-torsional buckling for beams under compression
Eccentric Loading
Real columns have axial load with eccentricity:
- e = eccentricity
- c = distance to extreme fiber
Secant Formula
For eccentrically loaded columns: