Column Buckling

Buckling is a mode of failure where a compressive member suddenly deflects laterally.


Critical Load

The load at which a perfectly straight column becomes unstable:

Pcr=π2EI(KL)2P_{cr} = \frac{\pi^2 EI}{(KL)^2}

  • E = Modulus of elasticity
  • I = Minimum second moment of area
  • L = Unbraced length
  • K = Effective length factor

Effective Length Factor (K)

End Conditions K
Both ends pinned 1.0
One end fixed, one free 2.0
Both ends fixed 0.5
One fixed, one pinned 0.7

Slenderness Ratio

λ=KLr\lambda = \frac{KL}{r}

  • r = radius of gyration = √(I/A)

Classification

Slenderness Behavior
Short (λ < 20) Material failure (crushing)
Intermediate (20 < λ < 100) Inelastic buckling
Long (λ > 100) Elastic buckling (Euler)

Euler Buckling Load

For long columns (elastic buckling):

PE=π2EI(KL)2P_E = \frac{\pi^2 EI}{(KL)^2}

Valid when:

λ>λlim=πEσy\lambda > \lambda_{lim} = \pi \sqrt{\frac{E}{\sigma_y}}


Johnson Buckling

For intermediate columns (inelastic):

Pcr=σyA[1−σy4π2E(KLr)2]P_{cr} = \sigma_y A \left[ 1 - \frac{\sigma_y}{4\pi^2 E} \left(\frac{KL}{r}\right)^2 \right]


Design Considerations

slenderness Ratio Limits

  • Steel: KL/r ≤ 200
  • Aluminum: KL/r ≤ 100-150
  • Concrete: slenderness < 100

Column Sections

  • Weak axis buckling — often critical (lowest I)
  • Use stiffened sections (I-beam, box)
  • Lateral-torsional buckling for beams under compression

Eccentric Loading

Real columns have axial load with eccentricity:

Pcr=PE1+ecr2P_{cr} = \frac{P_E}{1 + \frac{e c}{r^2}}

  • e = eccentricity
  • c = distance to extreme fiber

Secant Formula

For eccentrically loaded columns:

σmax=PA[1+ecr2sec⁡(KL2rPAE)]\sigma_{max} = \frac{P}{A} \left[ 1 + \frac{e c}{r^2} \sec\left(\frac{KL}{2r}\sqrt{\frac{P}{AE}}\right) \right]